Samuel Mazin
Ewing Marion Kauffman Postdoctoral Fellow, Stanford University
Radiology
- Office
- Richard M. Lucas Center for Imaging
1201 Welch Road
Stanford, CA 94305
- Research Areas
- Emission guided radiation therapy
- Medical imaging, and computed tomography (CT) in particular
- Reconstruction algorithms
- Reduction of metal artifacts
- CT system design
- Journal Papers
- S.R. Mazin, N.J. Pelc, "Fourier rebinning algorithm for inverse geometry CT", Medical Physics vol. 35(11), pp. 4857-4862, 2008.
- R. Rakow-Penner, G. Gold, B. Daniel, K. Stevens, J. Rosenberg, S.R. Mazin, J. Pauly, G.H. Glover "Reduction of truncation artifacts in rapid 3D articular cartilage imaging", J Magn Reson Imag, vol. 27(4), pp. 860-5, 2008.
- S.R. Mazin, J. Star-Lack, N.R. Bennett, N.J. Pelc, "Inverse-geometry volumetric CT system with multiple detector arrays for wide field-of-view imaging", Medical Physics vol. 34, pp. 2133-2142, 2007.
- T.G. Schmidt, J. Star-Lack, N.R. Bennett, S.R. Mazin, E. Solomon, R. Fahrig, N.J. Pelc, "A prototype table-top inverse-geometry volumetric CT system", Medical Physics vol. 33, pp. 1867-1878, 2006.
- Conference Papers
- S.R. Mazin, T.G. Schmidt, E. Solomon, R. Fahrig, N.J. Pelc, "Geometry analysis of an inverse-geometry volumetric CT system with multiple detector arrays," in Medical Imaging 2004: Physics of Medical Imaging, Proc. SPIE vol. 5368, pp. 320-329, 2004.
- S.R. Mazin, T.G. Schmidt, N.J. Pelc, "Collimator for a multiple-eye inverse-geometry volumetric CT system", RSNA, Chicago, IL, 2004.
- T.G. Schmidt, N.R. Bennett, S.R. Mazin, J. Star-Lack, E. Solomon, N.J. Pelc, "First images from a table-top inverse geometry volumetric CT system with a large-area scanned source", RSNA, Chicago, IL, 2004.
- S.R. Mazin, T.G. Schmidt, E. Solomon, R. Fahrig, N.J. Pelc, "2D simulations of an inverse-geometry volumetric CT system with multiple detector arrays," in Medical Imaging 2005: Physics of Medical
Imaging, Proc. SPIE vol. 5745, pp. 889-897, 2005.
- T.G. Schmidt, N.R. Bennet, S.R. Mazin, J. Star-Lack, E. Solomon, N.J. Pelc, "MTF analysis of a prototype table-top inverse-geometry volumetric CT system", Medical Imaging 2005: Physics of Medical Imaging, Proc. SPIE vol. 5745, pp. 171-178, 2005.
- S.R. Mazin, J. Star-Lack, N.R. Bennett, T.G. Schmidt, N.J. Pelc, "Wider eld-of-view inverse- geometry CT with multiple detector arrays: initial experimental results", RSNA, Chicago, IL, 2005.
- T.G. Schmidt, J. Star-Lack, N.R. Bennett, E. Solomon, S.R. Mazin, N.J. Pelc, "Investigation of a prototype table-top inverse-geometry volumetric CT system", RSNA, Chicago, IL, 2005.
- S.R. Mazin, N.J. Pelc, "Motion artifacts from an inverse-geometry CT system with multiple detector arrays", Medical Imaging 2006: Physics of Medical Imaging, Proc. SPIE vol. 6142, pp. 143-150, 2006.
- S.R. Mazin, N.J. Pelc, "Adaptation of a fast 3D PET reconstruction algorithm to an inverse-geometry CT system,", IEEE NSS/MIC, San Diego, CA, 2006.
- S.R. Mazin, N.J. Pelc, "A fast 3D reconstruction algorithm for inverse-geometry CT based on an exact PET rebinning algorithm", Medical Imaging 2007: Physics of Medical Imaging, Proc. SPIE vol. 6510, pp. 65105C, 2007.
- S.R. Mazin, N.J. Pelc, "A Fourier rebinning algorithm for cone-beam CT", Proc. SPIE: Physics of Medical Imaging vol. 6913, pp. 691323, 2008.
- S.R. Mazin, N.J. Pelc, "Metal artifact reduction algorithm for
X-ray CT using a three-pass approach", Med. Phys. 36, pp. 2432, 2009.
- Curriculum Vitae
- Lab
-
last updated July 27,2008